The hydraulics viewer does not appear on the screen.

When running the Hydraulics command, the Hydraulics Viewer appears in the Windows Taskbar but is not visible on the screen. The Maximize selection is not available when right mouse clicking on the icon.

  1. Click on the Windows Start button.
  2. Click on All Programs and then Accessories.
  3. Click on the Run command.
  4. In the Run dialog box, type regedit and click on the Open button to open the system registry.
  5. In the system Registry Editor, locate the HKEY_LOCAL_MACHINE\SOFTWARE\Software Republic\RCLI 5 AutoCAD folder.
  6. Click on the folder name and in the area to the right, look for FormCalcHydraulicsViewer under the Name column.
  7. Right mouse click on FormCalcHydraulicsViewer and choose Delete from the resulting popup menu.
  8. Answer Yes to delete the registry entry.
  9. Close the system Registry Editor.
  10. Restart AutoCAD and try the command again.