| Installing the latest update file includes all previous patches for this version of the software. |
| |
| |
|
Solved a problem with specialty strip nozzles during distribution analysis.
|
| |
| |
|
Improved the left and right scroll bar in the Automatic Pipe Sizing for Mainline and Hydraulic Calculations dialog boxes.
|
| |
| |
|
Changed the General Notes in the Plants Database from 255 characters to an unlimited number of characters.
Added the ability to associate an image with a plant in the Plants Database.
Added the ability to create Plant Palettes and the ability to assign one or more plants to each palette in the Plants Database.
Added the ability to sort plants by Palette name in the Plant Placement dialog box.
Added the ability to insert the image assigned to a plant into the drawing in the Plant Placement dialog box.
Created the ability to list both the common and botanical name in the plant legend using the Create Legend command.
Separated the Plant Size from the Common or Botanical name in the legend.
When placing a plant symbol on the design, you can now see the symbol during the placement process.
When placing sprinkler symbols on the design, there is a visual representation to assist in the placement process.
|
| |
| |
|
Adjusted Quantity Label command for hatched plantings.
|
| |
| |
Drip Tubing Placement will now automatically select the last tubing used.
Added pipe layer naming options to the Irrigation Preferences. Pipe can now be seperated with the following layer naming options:
[Mainline/Lateral Line] [Pipe Class] [Pipe Size]
[Mainline/Lateral Line] [Pipe Class]
[Mainline/Lateral Line] [Pipe Size]
[Mainline/Lateral Line]
[Pipe Class] [Pipe Size]
[Pipe Class]
[Pipe Size]
[All Pipe On Single "Pipe" Layer]
|
| |
| |
|
Updated the Drip Tubing Database to allow for 4 decimal places when entering flow.
|
| |
| |
|
Further adjustments to the Control Valves database.
|
| |
| |
|
Fixed an Invalid use of NULL error when adding a new control valve to the Control Valves database.
|
| |
| |
|
Fixed a problem when the density setting in the distribution analysis is somehow deleted from the database.
Resolved a conversion problem when entering the flow rate in l/hr in the Drip Tubing Database.
Adjusted the Circular Layout command to place emission devices on any selected block. The devices are placed based on the insertion point of the block.
|
| |
| |
|
Had a problem with AutoCAD® selecting items on large drawings during the Material/Estimate command.
|
| |
| |
|
Fixed a problem with adding a controller to the Controllers Database.
|
| |
| |
|
Fixed a problem with layer assignments for mainline pipe during the automatic pipe sizing process.
Solved a problem with adding pipe to a Custom category receiving a Run-time error 9: Subscipt out of range error message.
Found a limitation of 256 pieces of pipe and sprinklers per lateral line branch in the Automatic Pipe Sizing command.
|
| |
| |
|
Made minor adjustments to the fittings takeoff in the Material/Estimate command.
Corrected a units conversion problem in the Material/Estimate and Legend commands for calculating the number of plants within a hatched area.
|
| |
| |
|
Solved a problem with the material takeoff not counting compression fittings.
|
| |
| |
|
Corrected a problem with precipitation rate calculations if sprinklers are assigned to different elevations.
Fixed a problem with the rotation and placement of symbols during the Auto Symbol Layout command.
Resolved a rare problem where multiple sprinklers may be positioned on top of each other when placing sprinklers automatically using the Within a Boundary command.
Solved a problem with text justification on the Quantity Label command.
Added a third decimal location to the Precipiation Rate information in the Performance Data for sprinklers.
|
| |
| |
|
Solved a problem with an Invalid Use of Null error message when sizing pipe with a custom pipe category.
|
| |
| |
|
In the Hydraulics Viewer, if you clicked on a piece of lateral line pipe the Pipe Type label read Mainline. If you clicked on a piece of mainline pipe, the label read Lateral Line.
Corrected a typo on a Pipe Hop error message.
|
| |
| |
|
Fixed a problem with placing plant hatching prior to placing a standard symbol.
|
| |
| |
|
Corrected a problem with the Drafting Tool not working when an angle is entered.
|
| |
| |
|
Fixed a problem with placing a pump symbol on the drawing screen.
|
| |